Central Tube Multimode Fiber Optic Riser Cable

Central Tube Riser Cable

RoHS Compliant Indoor Outdoor Fiber Optical CablesIndoor/Outdoor Fiber Optic Cable

  • UV Resistant Jacket
  • Gel Filled Central Tube Provides Protection Against Water Penetration
  • Dry, Super Absorbent Polymers (SAPs) Eliminate Water Migration in Cable Interstices
  • Suitable for Lashed Aerial, Duct, Underground Conduit and Indoor Riser Applications

  • Features
  • Part Numbers
  • Applications
  • Specifications

Central Tube Cable Features

  • Cables with Improved Attenuation Available
  • Low Smoke Zero Halogen Available
  • Cables with Extended 10 Gigabit Ethernet Support Distances Available
Central Tube Fiber Optic Cable Diagram
Dielectric Materials Riser
Overall Jacket Flame-Retardant Thermoplastic
Fiber Count62.5 UM OM150 UM OM250 UM OM350 UM OM48.3 UM OS28.3 UM OS2BI
260103-260104-260337-261837-260105-261723-2
460103-460104-460337-461837-460105-461723-4
660103-660104-660337-661837-660105-661723-6
860103-860104-860337-861837-860105-861723-8
1060103-1060104-1060337-1061837-1060105-1061723-10
1260103-1260104-1260337-1261837-1260105-1261723-12

Central Tube Cable Applications

  • Indoor / Outdoor Applications where Gel-Filled Cables are Suitable for Best Water-Blocking
  • Robust Cables for Indoor Applications where the Cable may be Subject to a Damp / Moist Environment
  • Indoor / Outdoor Applications where Termination via Pigtail Splicing is Preferred
  • Suitable for Lashed Aerial, Duct, Underground Conduit and Indoor Riser Applications

Fiber Distances by Application (conventional), pre-QSFP Release
Fiber Distances & Loss Budgets by Application (Based on QSFP Rev. 1 Specification Dec. 2006)
Understanding OM1, OM2, OM3, OS1 and OS2 Glass Types

Download PDF Specification on Central Tube Multimode Fiber Optic Cables

Central Tube Cable Optical Specifications

TIA/EIA-568-B.3/B.3-1
ISO/IEC 11801, 2nd Edition
Bellcore GR-409-CORE
HCM Fiber Performance ParametersMax Attenuation (dB/Km)Min Bandwidth OFL MHz-KmMin Bandwidth* MHz-KmGigabit Ethernet Support Distance (meters)10 Gigabit Ethernet Support Distance (meters)
 850 nm1300 nm850 nm1300 nm850 nm1300 nm850 nm1300 nm850 nm1300 nm
OM13.251.0200500220na30055033na
OM23.251.0700500850na750550150na
OM33.01.015005002000na1000550300na
OM43.01.035005004700na1100550550na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.          
           
 1310 nm1550 nm        
OS20.350.25        
OS2 BI**0.350.25        
**OS2 BI unilizes bend-insensitive optical glass         

Central Tube Cable Mechanical Specifications

FIBER COUNTCABLE O.D. MAXIMUM LOAD INSTALLOPERATION CABLE WEIGHT
 in.mmlbs-fNlbs-fNlbs/1000 ftkg/1000m
2.2877.2300133515066739.458.7
4.2877.2300133515066739.458.7
6.2877.2300133515066739.458.7
8.2877.2300133515066739.558.8
10.2877.2300133515066739.558.8
12.2877.2300133515066739.658.8